Tripp Lite UPS SU12000RT4UHW Hot-Swappable Modular 12000VA 50A 4U Rack/Tower Retail
- SKU: 106536
- Vendor: Tripp Lite
- UPC: 037332154873
4U power module and 4U external battery pack installs in 8 rack spaces (8U). Upright tower and two-post rackmount installation supported with optional accessories. Maintains full-time sine wave output within 3% of selectable 208/120 or 240/120V AC. Corrects brownouts and overvoltages from 65V to 140V (L-N).
Expandable runtime with optional external battery packs. Converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types.
Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Network-grade AC surge and noise suppression. Network management interfaces include combination DB9 RS-232 enabled and dry contact serial port, enhanced USB port and SNMPWEBCARD slot.
HID-compliant USB interface enables integration with built-in power management and auto-shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all three network interfaces.
OUTPUT
Output Volt Amp Capacity (VA) : 12000
Output kVA capacity (kVA) : 12
Output Watt Capacity (watts) : 8400
Output kW capacity : 8.4
Output power factor : 0.7
Output Capacity Details : 12,000 VA (240V) / 10,395 VA (208V) / 8,400 watts (208/240V)
Crest Factor : 3:1
Nominal Output Voltage(s) Supported : 120V 208V 240V
Nominal Voltage details : 240/120V or 208/120V split phase output
Frequency compatibility : 60 Hz
Output voltage regulation (line mode) : +/- 3%
Output voltage regulation (Economy line mode) : +/- 10%
Output voltage regulation (Battery mode) : +/- 3%
Built-in UPS output receptacles : Hardwire
Output AC waveform (AC mode) : Sine wave
INPUT
Rated input current (at maximum load) : 50A
Nominal Input Voltage(s) Supported :
208V AC / 120V AC (4 wire split single phase) 240V AC /120V AC (4 wire split single phase)
UPS input connection type : Hardwire
UPS input connection description : 4 wire split-phase input (L1, L2, N, G)
Recommended Electrical Service : 50A 208/240-120 Split Phase
BATTERY
Full load runtime (minutes) : 7 min. (8400w)
Half load runtime (minutes) : 20 min. (2400w)
Expandable battery runtime : Supports extended runtime with optional external battery packs
External battery pack compatibility
BP192V18-4U BP192V557C-16K BP192V787C-16K BP192V1037C-16K BP192V1407C-16K
DC system voltage (VDC) : 192
Battery recharge rate (included batteries) : Less than 6 hours from 10% to 80%
Battery replacement description : Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description :
Online, double-conversion power conditioning
Overvoltage correction :
3% output voltage regulation during overvoltages to 140 (measured L1-N : L2-N)
Undervoltage correction :
3% output voltage regulation during undervoltages to 65 (measured L1-N : L2-N)
LEDS ALARMS AND SWITCHES
LED Indicators :
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status LCD screen offers additional information and control options
Alarms :
Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation :
Alarm cancel switch
Switches :
2 Switches control off/on power status and alarm-cancel/self-test operation 2 additional switches support set and execute scrolling LCD functions bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
SURGE / NOISE SUPPRESSION
UPS AC suppression response time : Instantaneous
EMI / RFI AC noise suppression : Yes
PHYSICAL
Included mounting accessory description :
2 sets of adjustable 4 post rack rails included
Installation form factors supported with optional accessories :
2 post rackmount (2POSTRMKITWM) Tower (2-9USTAND)
Primary form factor : Rackmount
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) :
7 x 17.5 x 40.5
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) :
17.8 x 44.4 x 102.9
Installed whole system maximum rack depth (inches) :
40.5
Installed whole system maximum rack depth (cm) :
102.9
Installed whole system total rack space height (rack spaces) :
8U
Secondary form factor :
Tower (requires 2-9USTAND)
UPS / Power Module weight (lbs) :
86
UPS / Power Module weight (kg) :
39
UPS dimensions details :
Includes 4U power module and 4U battery pack
Included battery pack dimensions (height x width x depth / inches) :
7 x 17.5 x 27.8
Included battery pack dimensions (height x width x depth / cm) :
17.7 x 44.4 x 70.6
Included battery pack weight (lbs) :
239
Included battery pack weight (kg) :
108.5
UPS Shipping dimensions (height x width x depth / inches) :
45.5 x 23.5 x 34.3
UPS Shipping dimensions (height x width x depth / cm) :
115.6 x 59.7 x 87.1
Shipping weight (lbs) :
448.8
Shipping weight (kg) :
203.8
UPS housing material :
Steel
Cooling method :
Fan
COMMUNICATIONS
Communications interface :
USB (HID enabled) DB9 Serial Contact closure EPO (emergency power off) Slot for SNMP/Web interface
Network monitoring port description :
RS232 and contact closure communications are supported on one DB9 port
PowerAlert software :
Included
Communications cable :
USB and DB9 cabling included
LINE / BATTERY TRANSFER
Transfer time : No transfer time (0 ms.) in online, double-conversion mode
Low voltage transfer to battery power (setpoint) : 65V (L1-N:L2-N)
High voltage transfer to battery power (setpoint) : 140V (L1-N:L2-N)
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure) :
Cold-start operation supported
High availability UPS features :
Automatic inverter bypass Manual bypass switch Detachable hot-swap PDU Hot swappable UPS power module Hot swappable batteries
Green and high efficiency features :
High efficiency economy mode operation Schedulable daily hours of economy mode operation
WARRANTY